Cable size and fuse calculator

Choose what you’re powering, at what voltage and how many metres from the battery it is, and see which cable and fuse it needs and how much voltage reaches the appliance.

What you’re powering

Line voltage

What you’re powering
Charging and power1,000 W inverter
Cooling
Water
Heating and air
Light and ventilation
Kitchen
Work and leisure
Outside

1,000 W of output at 90% efficiency: it takes 1,111 W from the battery.

Metres of cable, one way only

The return run through the negative is already counted: the cable is twice as long.

How is it calculated?

First, the current: amps = watts ÷ volts. A 1,000 W inverter runs at 90% efficiency, so it takes about 1,111 W from the battery: at 12 V that’s 93 A, and at 24 V, half. That’s why big loads call for a higher system voltage.

The fuse goes 25% above that current, at the next standard size (5, 7.5, 10, 15, 20, 25, 30, 40, 50 A…). Some appliances need a minimum because of their start-up surge: the compressor fridge and the diesel heater, 15 A.

The fuse protects the cable, not the appliance: if there’s a short circuit or the appliance fails, it blows before the cable heats up and catches fire. So the cable has to carry the fuse’s current, not just the appliance’s. The figures are cautious ones for flexible copper cable running in trunking alongside others: 16 A with 1.5 mm², 40 A with 6 mm², 110 A with 25 mm², 300 A with 120 mm²…

Voltage drop: the cable is a resistor, and the current loses volts on the way there and on the way back. Drop (V) = 2 × L × I × ρ ÷ S, where L is the one-way length in metres, I the amps, S the cable size in mm² and ρ = 0.0175 Ω·mm²/m, the resistivity of copper. Divided by the line voltage, it gives the percentage.

We pick the thinnest standard size that does both: it carries the fuse’s current and loses 3.0% at most. Never below 1.5 mm²: any thinner and the cable gets damaged going through the bodywork. When the drop decides, moving the appliance closer to the battery slims the cable more than anything else.

At 230 V, after the inverter, there’s a circuit breaker of at least 16 A, with at least 2.5 mm² of cable. Panels in parallel run at about 18 V up to the charge controller.

This is a rule of thumb for design, not a standard: the installation has to be done and checked by a professional, with the cables and fuses each appliance’s maker asks for.

Sources: Victron Energy (Victron Energy, “Wiring Unlimited” (rev. 06): cable resistance, voltage drop, raising the voltage with big inverters and what the fuse is for) (opens in a new tab)Caledonian Cables (Caledonian Cables, H07V-K cable: insulation thickness and outer diameter of each size (the real-size drawing)) (opens in a new tab)Wikipedia (AWG gauges and their size in mm² (Wikipedia, “American wire gauge”)) (opens in a new tab)Dometic, Webasto, TrumaThetford (Thetford, N4080 and N4090 absorption fridges (2025 spec sheet): 140 W at most at 12 V; its N4000 installation manual asks for a 25 A fuse for the 12 V element and the cable size by length (4 mm² up to 2.5 m, 6 mm² up to 3.5 m and 10 mm² up to 6 m)) (opens in a new tab)Dometic (Dometic CoolAir RTX 1000 12 V: 10 to 50 A while cooling (maker’s spec sheet)) (opens in a new tab)ARB (ARB, technical specifications of its compressors: the CKMA12 draws 32 A at maximum load) (opens in a new tab)Kota Camper